التعرف على صلاحية البروسسور من العديد من المظاهر وسنأخذ الأوميجا STi5518 على سبيل المثال
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
ومن هذه المظاهر السخونة الزائدة
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وترتبط هذه الظاهرة غالبا بهبوط أحد الضغوط المغذية للبرسسور
وهناك نوعان من الجهود التي تغذي الأوميجا STi5518 :
(3.3 فولت VDD3_3 ) ويتم قياسها على الأطراف 4, 47, 81, 107,136, 159, 184
(2.5 فولت VDD2_5 ) ويتم قياسها على الأطراف 14, 37, 64, 94,119, 149, 171، 198
وهبوط أحد هذه الجهود الي أقل من 1 فولت (وقد تصل الى الصفر في حالة وجود قصر داخلي short ) مع السخونة الزائدة يعطي مؤشرات لتلف داخلي للأوميجا
وعند إجراء إختبارات قياس الجهد وقبل الحكم على تلف البرسسور
يجب الأخذ في الإعتبار التأكد أولا من سلامة هذه الجهود من وحدة التغذية أصلا
ويمكن عمل إختبار لها بفصل الخط المغذي للبرسسور والقياس بدون تحميل ، كما يراعى التأكد من سلامة الموحدات ( الثنائيات ) المسئولة عن هذه الجهود وكذا الزينرات أو الرجيولاتورز المسئولة عن تنظيم الجهد ، والتأكد وعدم وجود أي ترشيح بها وكذا مكثفات التنعيم الخاصة ويفضل إستبدالها بموحدات ومكثفات جديدة ومنظمات جديدة حتى ولو كانت قياستها صحيحة
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
2- إنخفاض درجة حرارة البرسسور بشكل ظاهر :
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
يشير إلى إحتمال غياب أحد هذه الجهود أو إنفصال أحد الأطراف ( الأرضي VSS ) وهي 5, 15, 38, 50, 65, 83, 96, 108, 121,137, 150, 160,172, 185, 199
وهنا يجب أن نفرق بين أمرين :
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
الأول : وهو توقف البرسسور عن العمل
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
ويكون البرسسور نفسة سليم والتوقف ناتج عن خلل بوحدة التغذية أو توقف المذبذب الكريستالي أو تلف الفلاش مموري أو البرنامج التشغيلي أو أحد المكونات المرتبطة بالبروسسور ( كمجموعة المكثفات والثنائيات ) أو إنفصال أحد الأرجل أو وجود أتربة ورطوبة عالية بالجهاز
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
الثاني : تلف البرسسور نفسه داخليا
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
حيث يتحتم تغييره
واليك أطراف الأوميجا STi5518
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img13.imageshack.us/img13/6370/90516103.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
أما الفلاش مموري يعتبر من الوحدات الأساسية المسئولة عن الذاكرة الرئيسية بالرسيفر وهو المسئول عن تخزين السوفتوير والباتشات وبيانات القنوات والإعدادات ومفاتيح ******* في الأجهزة التي تفتح بدون كارت عامة علاوة على اللودر والذي بدونه لا يمكن تحميل اي سوفتوير للرسيفر ، و تلف الفلاش يعني جهاز بدون قوائم وبدون قنوات وبدون بيانات على اللوحة بواجهة الجهاز الأمامية ، مع عدم الإستجابة للتحديث بالسوفتوير ، رغم سلامة الضغوط بما فيها الجهد 3,3 المغذي للفلاش وقد يكون التوقف ناتج عن خلل بوحدة التغذية أو توقف المذبذب الكريستالي أو تلف البروسسور أو فقدان البرنامج التشغيلي ( السوفتوير)
أو نتيجة تلف المكونات المرتبطة بالفلاش كمجموعة المكثفات والمقاوات أو إنفصال أحد الأرجل أو وجود أتربة ورطوبة عالية بالجهاز
ولنا عودة أخرى معها لنتعرف على طرق شحن الفلاش وكيفية نقل البيانات والتحديثات للرسيفر ودلالات الرسائل التي تظهر على واجهته الأمامية
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وحدة التغذية POWER SUPPLY
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
التيار المستخدم في تشغيل الوحدات الإلكترونية المختلفة كوحدات الذاكرة والتكبير والمذبذبات والمتحكمات داخل أي جهاز، هو تيار كهربي مستمر ( DC ) ، هذا التيار يمكن الحصول عليه من مصادر متعددة منها البطاريات أو من وحدات انتاج التيار والجهد المستمر والتي تعرف بوحدة التغذية POWER SUPPLY وهي تنتج تيار متعدد الجهود ، فلكل وحدة الكترونية داخل كل جهاز ، جهدا خاصا يكون مسئولا عن تشغيلها وقد يختلف هذا الجهد في قيمته عن الجهد المسئول عن تشغيل بعض الوحدات الأخرى داخل نفس الجهاز
وتعتبر وحدة التغذية هي المسئولة عن خفض جهد المنبع ذو التيار المتردد ( 220 فولت ) وإنتاج هذه الجهود من التيار المستمر لتلبية حاجة الوحدات الإلكترونية المختلفة
وأبسط نموذج لوحدة تغذية هو مانراه بهذه الدائرة والتي تسمي وحدة تغذية تعمل بموحد تيار نصف موجة Half Wave Rectifier
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img16.imageshack.us/img16/5199/33127505.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
حيث يوصل أخد أطراف الملف الثانوي بموحد سيليكوني والطرف الآخر بالأرضي
أما هذه الدائرة فتعرف بدائرة تغذية تعمل بموحد موجة كاملة Full Wave Center Tapped
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img31.imageshack.us/img31/8447/75766601.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه الدائرة تستخدم لإنتاج جهد موجب وجهد سالب من نفس المنبع Dual Voltage Supply
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img101.imageshack.us/img101/6805/41084732.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه الدائرة لتوحيد موجة كاملة وهي دائرة تغذية غير محكومة يحمل فيها التيار المستمر الناتج بما يعرف بالتعرجات
ripple وهي عبارة عن قمم الموجات الجيبية للتيار المتردد الذي تم تقويمه
Unregulated Linear Power Supply
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img13.imageshack.us/img13/3183/46075788.gif
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
أما هذه فدائرة محكومة Regulated Linear Supply ويخرج منها الجهد المستمر بشكل منتظم بدون تعرجات ripple
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img31.imageshack.us/img31/953/67515204.gif
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه عدة صور لدوائر تغذية محكومة تعرف ب (Switch Mode Power Supplies (SMPS)
ويتم فيها التخلص من ضغط التعرجات بشكل كامل وفيها يستخدم محول يتم عن طريقه خفض الجهد المتقطع الناتج عن دائرة تقطيع كما سيأتي شرحه
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img175.imageshack.us/img175/2678/77020860.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img13.imageshack.us/img13/3420/82121177.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img15.imageshack.us/img15/316/81839867.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img9.imageshack.us/img9/4959/58016314.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه دائرة فعلية تستخدم top224p
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img256.imageshack.us/img256/2326/28222063.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه دائرة جهاز رسيفرهيوماكس
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img18.imageshack.us/img18/5715/79332533.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وتقوم فكرة هذا النوع من وحدات التغذية على إستخدام محول يعرف ب Flyback power transformer
ومقطع للتيار عبارة عن Transistor من نوع Mosfetومعه درايفر Driver
أشكال مختلفة لمحولات Flyback power transformer
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img9.imageshack.us/img9/6171/77574654.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
يتم تحويل الجهد المتردد ( جهد المنبع) وقدره 220 فولت الى جهد مستمر تصل قيمته الى 300 فولت عن طريق إمراره من خلال قنطرة التوحيد D1 – D4 ثم على مكثف كبميائي ( الكتروليتي) ويوصل الجهد الموجب إلى الملف الابتدائي للمحول بينما يوصل الجهد السالب إلى ترانزستور المقطع switching transistorوهو المسئول عن تقطيع الجهد السالب وتوصيله للطرف الثاني من الملف الإبتدائي
وعليه فإنه يمر تيار متقطع (متردد) خلال الملف اللإبتدائي للمحول ( يتم نقطيع التيار المستمر الأصلي وجهده 300 فولت) هذا التيار يقطع الملفات الثانوية للمحول فيتولد على طرفيها جهدا متغيرا تتناسب قيمته مع عدد لفات الملف الثانوي ، ويتم توحيد هذا التيار بمرحلة التيار المنخفض عن طريق موحدات ثانوية ( D7 – D9 - D10 - D11 - D12 ( لتعطي جهودا قدرها 30،23 ، 17، 8،5 ، 4،3 ،15 فولت تيار مستمر
التعرف على سلامة وحدة التغذية :
التوقف الكلي لوحدة التغذية يعني شلل كامل للجهاز والتوقف الكامل معناه عدم وجود أي جهود بمرحلة التيار المنخفض ( من خرج المحول )
أما التوقف الجزئي فيعني غياب جهد أو أكثر من جهود التيار المنخفض
فإذا حدث توقف كلى للوحدة فيتم أولا التأكد من وجود الجهد 300 فولت على طرفى المكثف C3 يتم قياس الجهود على أطراف Q1 كما هي مبينة بالدائرة المرفقة ويجب ان تتطايق جميع القياسات المأخوذة مع مثيلتها بالدائرة ، ووجود أى إختلاف يعنى وجود الخلل إما في Q1 نفسه فيتم استبداله بآخر سليم ويجب التأكد من سلامة تغذيته بال +300 فولت ( رجل 3 )عبر المحول وعبر الملف BD1 ، كما يتم التأكد من وجود الجهد +15 على الرجل رقم 2 ومصدره المقاومة R2 كما يراجع الزنر Z02 بقياس فولت قدره 2و1 على رجل رقم4 .
وعموما وجود الجهد السالب (-5و0) بين (D6 , R4 ) يشير أن هذا الجزء يعمل بإنتظام .
قد يؤدي حدوث دائرة قصر في مرحلة الجهد المنخفض الى توقف كلى بالوحدة ، لذلك تراجع المكثفات الكيمائية وثنائيات التوحيد الخاصة بالجهد المنخفض .
إذا استمر العطل تستبدل OPT1 ,IC1 .
غياب هذا الجهد ( 300 فولت ) يعني وجود تلفا إما بالقنطرة (1) أو أي مكون سابق لها (2) ملف - (3) فيوز...الخ)
إذا تأكدت من تلف القنطرة أو عند إحتراق الفيوز يراجع المكثف C3 لإحتمال وجود دائرة قصر به او بالمراحل التالية له قبل تغيير القنطرة .
ووجود هذا الضغط يعني سلامة المراحل السابقة
ملاحظات عامة
1- معظم أعطال وحدة التغذية قد تنشأ غالبا نتيجة حدوث دائرة قصر بأحد المكونات ( مكثف - ثنائى توحيد - ثنائي زنر ) او نتيجة حدوث انهيار Break Down بأحد العناصر الفعالة كالترانزستورات أو الزنرات أو الدوائر المتكاملة ومن مظاهر هذا العطل وجود سخونة شديدة أو تفحم كامل بأحد المقاومات مثل R21 بالدائرة السابقة
2- قبل تغيير أي عنصر يجب التأكد من زوال سبب العطل أولا حتى لا يتلف العنصر الجديد.
3- يراعى عند تغيير أي عنصر بآخر جديد ان يكون بذات الرقم والقيمة و بنفس المواصفات للقطعة المستبدلة .
4- يراعى تثبيت الاجزاء التي تركب علي أجسام تبريد بشكل جيد .
5- تستعمل دائما كاوية لحام ذات وات منخفض ويستعمل قصدير وفلاكس من نوع جيد ويتم التخلص من القصدير الزائد بإستخدام شفاط قصدير.
6- يجب الحذر من لمس الأجزاء بالشاسيه الساخن ( مرحلة الجهد المرتفع ) باليد تجنبا للصدمة الكهربائية الشديدة
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
شرح عمل دائرة وحدة تغذية عملية تستخدم وحدة TOP221-227 كمقطع للتيار مع محول flyback transformer
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img155.imageshack.us/img155/6746/12890629.png
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
اسنتى هنكمل الباقى اوعى تزهق
http://img116.imageshack.us/img116/9981/moraqaba1ndmk2fe8.gifhttp://img116.imageshack.us/img116/9981/moraqaba1ndmk2fe8.gifhttp://img116.imageshack.us/img116/9981/moraqaba1ndmk2fe8.gif
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
مــصــراوى ســــات
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img354.imageshack.us/img354/5434/as01120701009sdsk1.gifhttp://img354.imageshack.us/img354/5434/as01120701009sdsk1.gifhttp://img354.imageshack.us/img354/5434/as01120701009sdsk1.gifhttp://img354.imageshack.us/img354/5434/as01120701009sdsk1.gif
http://img341.imageshack.us/img341/9444/w6ww6w200504242138278a2kd6.gifأحبائى فى اللهhttp://img513.imageshack.us/img513/5495/w6ww6w20050424213720951ec6.gif
أقدم لكم اليوم
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
التعرف على صلاحية البروسسور من العديد من المظاهر وسنأخذ الأوميجا STi5518 على سبيل المثال
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
ومن هذه المظاهر السخونة الزائدة
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وترتبط هذه الظاهرة غالبا بهبوط أحد الضغوط المغذية للبرسسور
وهناك نوعان من الجهود التي تغذي الأوميجا STi5518 :
(3.3 فولت VDD3_3 ) ويتم قياسها على الأطراف 4, 47, 81, 107,136, 159, 184
(2.5 فولت VDD2_5 ) ويتم قياسها على الأطراف 14, 37, 64, 94,119, 149, 171، 198
وهبوط أحد هذه الجهود الي أقل من 1 فولت (وقد تصل الى الصفر في حالة وجود قصر داخلي short ) مع السخونة الزائدة يعطي مؤشرات لتلف داخلي للأوميجا
وعند إجراء إختبارات قياس الجهد وقبل الحكم على تلف البرسسور
يجب الأخذ في الإعتبار التأكد أولا من سلامة هذه الجهود من وحدة التغذية أصلا
ويمكن عمل إختبار لها بفصل الخط المغذي للبرسسور والقياس بدون تحميل ، كما يراعى التأكد من سلامة الموحدات ( الثنائيات ) المسئولة عن هذه الجهود وكذا الزينرات أو الرجيولاتورز المسئولة عن تنظيم الجهد ، والتأكد وعدم وجود أي ترشيح بها وكذا مكثفات التنعيم الخاصة ويفضل إستبدالها بموحدات ومكثفات جديدة ومنظمات جديدة حتى ولو كانت قياستها صحيحة
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
2- إنخفاض درجة حرارة البرسسور بشكل ظاهر :
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
يشير إلى إحتمال غياب أحد هذه الجهود أو إنفصال أحد الأطراف ( الأرضي VSS ) وهي 5, 15, 38, 50, 65, 83, 96, 108, 121,137, 150, 160,172, 185, 199
وهنا يجب أن نفرق بين أمرين :
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
الأول : وهو توقف البرسسور عن العمل
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
ويكون البرسسور نفسة سليم والتوقف ناتج عن خلل بوحدة التغذية أو توقف المذبذب الكريستالي أو تلف الفلاش مموري أو البرنامج التشغيلي أو أحد المكونات المرتبطة بالبروسسور ( كمجموعة المكثفات والثنائيات ) أو إنفصال أحد الأرجل أو وجود أتربة ورطوبة عالية بالجهاز
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
الثاني : تلف البرسسور نفسه داخليا
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
حيث يتحتم تغييره
واليك أطراف الأوميجا STi5518
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img13.imageshack.us/img13/6370/90516103.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
أما الفلاش مموري يعتبر من الوحدات الأساسية المسئولة عن الذاكرة الرئيسية بالرسيفر وهو المسئول عن تخزين السوفتوير والباتشات وبيانات القنوات والإعدادات ومفاتيح ******* في الأجهزة التي تفتح بدون كارت عامة علاوة على اللودر والذي بدونه لا يمكن تحميل اي سوفتوير للرسيفر ، و تلف الفلاش يعني جهاز بدون قوائم وبدون قنوات وبدون بيانات على اللوحة بواجهة الجهاز الأمامية ، مع عدم الإستجابة للتحديث بالسوفتوير ، رغم سلامة الضغوط بما فيها الجهد 3,3 المغذي للفلاش وقد يكون التوقف ناتج عن خلل بوحدة التغذية أو توقف المذبذب الكريستالي أو تلف البروسسور أو فقدان البرنامج التشغيلي ( السوفتوير)
أو نتيجة تلف المكونات المرتبطة بالفلاش كمجموعة المكثفات والمقاوات أو إنفصال أحد الأرجل أو وجود أتربة ورطوبة عالية بالجهاز
ولنا عودة أخرى معها لنتعرف على طرق شحن الفلاش وكيفية نقل البيانات والتحديثات للرسيفر ودلالات الرسائل التي تظهر على واجهته الأمامية
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وحدة التغذية POWER SUPPLY
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
التيار المستخدم في تشغيل الوحدات الإلكترونية المختلفة كوحدات الذاكرة والتكبير والمذبذبات والمتحكمات داخل أي جهاز، هو تيار كهربي مستمر ( DC ) ، هذا التيار يمكن الحصول عليه من مصادر متعددة منها البطاريات أو من وحدات انتاج التيار والجهد المستمر والتي تعرف بوحدة التغذية POWER SUPPLY وهي تنتج تيار متعدد الجهود ، فلكل وحدة الكترونية داخل كل جهاز ، جهدا خاصا يكون مسئولا عن تشغيلها وقد يختلف هذا الجهد في قيمته عن الجهد المسئول عن تشغيل بعض الوحدات الأخرى داخل نفس الجهاز
وتعتبر وحدة التغذية هي المسئولة عن خفض جهد المنبع ذو التيار المتردد ( 220 فولت ) وإنتاج هذه الجهود من التيار المستمر لتلبية حاجة الوحدات الإلكترونية المختلفة
وأبسط نموذج لوحدة تغذية هو مانراه بهذه الدائرة والتي تسمي وحدة تغذية تعمل بموحد تيار نصف موجة Half Wave Rectifier
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img16.imageshack.us/img16/5199/33127505.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
حيث يوصل أخد أطراف الملف الثانوي بموحد سيليكوني والطرف الآخر بالأرضي
أما هذه الدائرة فتعرف بدائرة تغذية تعمل بموحد موجة كاملة Full Wave Center Tapped
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img31.imageshack.us/img31/8447/75766601.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه الدائرة تستخدم لإنتاج جهد موجب وجهد سالب من نفس المنبع Dual Voltage Supply
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img101.imageshack.us/img101/6805/41084732.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه الدائرة لتوحيد موجة كاملة وهي دائرة تغذية غير محكومة يحمل فيها التيار المستمر الناتج بما يعرف بالتعرجات
ripple وهي عبارة عن قمم الموجات الجيبية للتيار المتردد الذي تم تقويمه
Unregulated Linear Power Supply
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img13.imageshack.us/img13/3183/46075788.gif
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
أما هذه فدائرة محكومة Regulated Linear Supply ويخرج منها الجهد المستمر بشكل منتظم بدون تعرجات ripple
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img31.imageshack.us/img31/953/67515204.gif
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه عدة صور لدوائر تغذية محكومة تعرف ب (Switch Mode Power Supplies (SMPS)
ويتم فيها التخلص من ضغط التعرجات بشكل كامل وفيها يستخدم محول يتم عن طريقه خفض الجهد المتقطع الناتج عن دائرة تقطيع كما سيأتي شرحه
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img175.imageshack.us/img175/2678/77020860.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img13.imageshack.us/img13/3420/82121177.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img15.imageshack.us/img15/316/81839867.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img9.imageshack.us/img9/4959/58016314.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه دائرة فعلية تستخدم top224p
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img256.imageshack.us/img256/2326/28222063.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وهذه دائرة جهاز رسيفرهيوماكس
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img18.imageshack.us/img18/5715/79332533.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
وتقوم فكرة هذا النوع من وحدات التغذية على إستخدام محول يعرف ب Flyback power transformer
ومقطع للتيار عبارة عن Transistor من نوع Mosfetومعه درايفر Driver
أشكال مختلفة لمحولات Flyback power transformer
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
http://img9.imageshack.us/img9/6171/77574654.jpg
http://img256.imageshack.us/img256/2199/28ov7fq0.gif
يتم تحويل الجهد المتردد ( جهد المنبع) وقدره 220 فولت الى جهد مستمر تصل قيمته الى 300 فولت عن طريق إمراره من خلال قنطرة التوحيد D1 – D4 ثم على مكثف كبميائي ( الكتروليتي) ويوصل الجهد الموجب إلى الملف الابتدائي للمحول بينما يوصل الجهد السالب إلى ترانزستور المقطع switching transistorوهو المسئول عن تقطيع الجهد السالب وتوصيله للطرف الثاني من الملف الإبتدائي
وعليه فإنه يمر تيار متقطع (متردد) خلال الملف اللإبتدائي للمحول ( يتم نقطيع التيار المستمر الأصلي وجهده 300 فولت) هذا التيار يقطع الملفات الثانوية للمحول فيتولد على طرفيها جهدا متغيرا تتناسب قيمته مع عدد لفات الملف الثانوي ، ويتم توحيد هذا التيار بمرحلة التيار المنخفض عن طريق موحدات ثانوية ( D7 – D9 - D10 - D11 - D12 ( لتعطي جهودا قدرها 30،23 ، 17، 8،5 ، 4،3 ،15 فولت تيار مستمر
التعرف على سلامة وحدة التغذية :
التوقف الكلي لوحدة التغذية يعني شلل كامل للجهاز والتوقف الكامل معناه عدم وجود أي جهود بمرحلة التيار المنخفض ( من خرج المحول )
أما التوقف الجزئي فيعني غياب جهد أو أكثر من جهود التيار المنخفض
فإذا حدث توقف كلى للوحدة فيتم أولا التأكد من وجود الجهد 300 فولت على طرفى المكثف C3 يتم قياس الجهود على أطراف Q1 كما هي مبينة بالدائرة المرفقة ويجب ان تتطايق جميع القياسات المأخوذة مع مثيلتها بالدائرة ، ووجود أى إختلاف يعنى وجود الخلل إما في Q1 نفسه فيتم استبداله بآخر سليم ويجب التأكد من سلامة تغذيته بال +300 فولت ( رجل 3 )عبر المحول وعبر الملف BD1 ، كما يتم التأكد من وجود الجهد +15 على الرجل رقم 2 ومصدره المقاومة R2 كما يراجع الزنر Z02 بقياس فولت قدره 2و1 على رجل رقم4 .
وعموما وجود الجهد السالب (-5و0) بين (D6 , R4 ) يشير أن هذا الجزء يعمل بإنتظام .
قد يؤدي حدوث دائرة قصر في مرحلة الجهد المنخفض الى توقف كلى بالوحدة ، لذلك تراجع المكثفات الكيمائية وثنائيات التوحيد الخاصة بالجهد المنخفض .
إذا استمر العطل تستبدل OPT1 ,IC1 .
غياب هذا الجهد ( 300 فولت ) يعني وجود تلفا إما بالقنطرة (1) أو أي مكون سابق لها (2) ملف - (3) فيوز...الخ)
إذا تأكدت من تلف القنطرة أو عند إحتراق الفيوز يراجع المكثف C3 لإحتمال وجود دائرة قصر به او بالمراحل التالية له قبل تغيير القنطرة .
ووجود هذا الضغط يعني سلامة المراحل السابقة
ملاحظات عامة
1- معظم أعطال وحدة التغذية قد تنشأ غالبا نتيجة حدوث دائرة قصر بأحد المكونات ( مكثف - ثنائى توحيد - ثنائي زنر ) او نتيجة حدوث انهيار Break Down بأحد العناصر الفعالة كالترانزستورات أو الزنرات أو الدوائر المتكاملة ومن مظاهر هذا العطل وجود سخونة شديدة أو تفحم كامل بأحد المقاومات مثل R21 بالدائرة السابقة
2- قبل تغيير أي عنصر يجب التأكد من زوال سبب العطل أولا حتى لا يتلف العنصر الجديد.
3- يراعى عند تغيير أي عنصر بآخر جديد ان يكون بذات الرقم والقيمة و بنفس المواصفات للقطعة المستبدلة .
4- يراعى تثبيت الاجزاء التي تركب علي أجسام تبريد بشكل جيد .
5- تستعمل دائما كاوية لحام ذات وات منخفض ويستعمل قصدير وفلاكس من نوع جيد ويتم التخلص من القصدير الزائد بإستخدام شفاط قصدير.
6- يجب الحذر من لمس الأجزاء بالشاسيه الساخن ( مرحلة الجهد المرتفع ) باليد تجنبا للصدمة الكهربائية الشديدة